Well Targeting for Geothermal Field Development based on.pdf
PUBLIC Open In Flip Book Devi Septia Nurul
This paper presents the gravity study which integrated with the results of other studies, such as geology,
reservoir, seismicity and geochemistry, in connection with the plan of development of geothermal power plant in the
TMS field. Integration of these studies is aimed to identify the fault structure and geothermal prospect area, which could
be used then to review the placement of production and injection wells. The results show that the geothermal prospect
areas is bounded by normal faults with N-S and NE-SW directions. In general, all proposed wells could be accepted
with some requirements. For production wells, the first and the second priority are well PN2 and PN3. While the third
priority is well PN1 in which this well need to be placed close to the fault with the depth is slightly greater. All injection
wells (I1, I2, I3 and I4) is located in the low residual anomaly and closed to the fault, so these wells have the same rank.