digilib@itb.ac.id +62 812 2508 8800

2015 EJRNL PP SHANGBI PENG 1.pdf)u
Terbatas Suharsiyah
» ITB

Based on the actual operational parameters of a subsea multiphase pipeline, an experimental study on the internal corrosion of a subsea multiphase pipeline was conducted in a dynamic, hightemperature autoclave, which had a similar environment to an actual field environment, using the partial pressure of CO2 (PCO2), velocity of the corrosion medium, temperature, corrosion time, and corrosion inhibitor as variables. The results show that CO2 resulted in severe localized corrosion and that the corrosion rate increased as the PCO2 and velocity increased; the corrosion rate first increased and then decreased with increasing temperature. The corrosion rate peaked at approximately 65 C and then decreased continuously afterwards; the corrosion rate decreased as the duration of the experimental period increased. Under the operational conditions of the selected subsea pipeline, localized corrosion caused by CO2 was still the primary corrosion risk. Several types of corrosion inhibitors could inhibit the occurrence of localized corrosion for a short time period; however, most corrosion inhibitors could not completely inhibit localized corrosion