ANALISIS PERBANDINGAN DATA HASIL PENGUKURAN BLOK SUDUT MENGGUNAKAN BATANG SINUS DAN LASER INTERFEROMETER

Data Comparison Analysis of Angle Gauge Measurement Using Sine Bar and Laser Interferometer

Undergraduate Theses from JBPTITBPP / 2009-02-13 15:35:36
Oleh : ZIDNY ILHAM HERNUADI (NIM 13103087), S1 - Department of Mechanical Engineering
Dibuat : 2008, dengan 7 file

Keyword : batang sinus, laser interferometer

Proses kalibrasi bertujuan untuk mengetahui kebenaran sifat-sifat suatu alat ukur. Pada dasarnya proses kalibrasi serupa dengan proses pengukuran, yaitu membandingkan suatu besaran dengan besaran lain yang dianggap lebih benar. Pada tugas akhir ini akan dilakukan kalibrasi laser interferometer dengan cara membandingkan data-data hasil pengukuran blok sudut menggunakan laser interferometer sebagai alat ukur yang ingin dianalisis dengan data-data hasil pengukuran blok sudut yang sama menggunakan batang sinus. Blok sudut disini memiliki fungsi sebagai alat ukur standar, dan jumlah blok sudut yang digunakan adalah sebanyak 12 buah dengan ukuran yang berbeda-beda. Sementara batang sinus yang digunakan untuk mengukur blok sudut memiliki dua ukuran yang berbeda yaitu batang sinus ukuran 200 mm dan batang sinus ukuran 300 mm. Hasil pengukuran blok sudut menggunakan dua batang sinus yang berbeda tersebut kemudian diperbandingkan untuk melihat batang sinus ukuran berapakah yang lebih tepat dan teliti. Batang sinus yang lebih tepat dan teliti tersebut yang nantinya digunakan sebagai pembanding laser interferometer. Untuk melakukan analisis perbandingan data digunakan beberapa metode analisis perbandingan data, yaitu metode perbandingan dua data, metode perbandingan k-data, dan metode analisis varian dengan dua jalan pengklasifikasian (annova two way of classification). Masing-masing metode memiliki fungsi tertentu dan digunakan untuk mendapatkan suatu kesimpulan yang tertentu pula. Dari hasil perbandingan data dapat diketahui apakah laser interferometer ataukah batang sinus yang lebih tepat dan lebih teliti di dalam penggunaannya sebagai alat ukur sudut. Bila hasil analisis menunjukkan data-data hasil pengukuran menggunakan laser interferometer memiliki ketelitian dan ketepatan yang lebih baik bila dibandingkan dengan data-data pengukuran menggunakan batang sinus, maka dapat dikatakan laser interferometer lebih tepat dan lebih teliti dibandingkan dengan batang sinus, dan sebaliknya.

Deskripsi Alternatif :

The purpose of calibration is to verify the characteristics of measurement devices. Basically, calibration process is similar with measurement process, as both are processes of comparing a certain unit to another unit, which is believed to have a "true value". Laser interferometer calibration is conducted by comparing data of angle gauge measurement using the laser interferometer itself, with data of angle gauge measurement using sine bar. Angle gauge has a function as a standard, and it has 12 different dimensions. Sine bars used have two different dimensions, 200 mm sine bar and 300 mm sine bar. Data of angle gauge measurement using both sine bars are compared and analyzed to get a result of the more accurate and precise sine bar. The sine bar with better accuracy and precision will then be used as comparator of laser interferometer. To execute data comparison analysis, several methods are used, two data comparison method, k-data comparison method, and analysis of variant with two way of classification method. Each has a specific purpose and used to get a specific conclusion as well. The result of data comparison analysis will give a conclusion whether laser interferometer or sine bar is more accurate and precise in its function as angle measurement device. If the result indicates that data of angle gauge measurement using the laser interferometer are more accurate and precise compared to data of angle gauge measurement using sine bar, then it can be concluded that laser interferometer is more accurate and more precise than the sine bar. On the contrary, the sine bar is more accurate and more precise than laser interferometer.

Copyrights : Copyright Â(c) 2001 by ITB Central Library. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS1 - Department of Mechanical Engineering
Nama KontakDrs. Mahmudin, SIP.
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOdigilib@lib.itb.ac.id