ABSTRAK:




Perusahaan Daerah Air Minum (PDAM) Dago Pakar merupakan salah satu instalasi yang melayani kebutuhan air minum di Kota Bandung. Saat ini PDAM Dago Pakar memiliki dua buah instalasi air minum. Salah satu instalasi pengolahannya merupakan sistem paket, yaitu instalasi pengolahan yang bukan dirancang berdasarkan karakteristik air yang akan diolah.




Kekurangcocokan instalasi pengolahan dengan karakteristik air yang akan diolah akan menyebabkan proses pengolahan tidak berjalan dengan baik, sehingga akan menurunkan efisiensi pengolahannya.




Maksud dan tujuan dari tugas akhir ini adalah mengevaluasi kinerja Instalasi Pengolahan Air Minum Dago Pakar serta melakukan modifikasi instalasi untuk menaikkan produktivitasnya, sehingga didapatkan desain pengembangan Instalasi Pengolahan Air Minum Miniplant Dago Pakar yang dapat membantu memenuhi kebutuhan air minum di wilayah Bandung Timur dan Selatan.




Observasi dan pengukuran di instalasi terbangun, yaitu meliputi peninjauan terhadap unit operasi dan proses yang terjadi pada instalasi pengolahan dan pengukuran dimensi unit-unit terbangun. Pengambilan sampel dilakukan untuk analisa kualitas air baku terhadap baku mutu air bersih menurut Peraturan Pemerintah No. 82 Tahun 2001, analisa kualitas air baku terhadap baku mutu air minum menurut PERMENKES No. 907/MENKES/SK/VII/2002. Hasil evaluasi terhadap unit-unit pengolahan terbangun menunjukkan bahwa kapasitas instalasi dapat dikembangkan lagi dari 42 L/dtk disesuaikan dengan kapasitas pompa yang ada menjadi 60 L/dtk. Modifikasi yang dilakukan diantaranya adalah: Perubahan dimensi unit flokulasi dengan panjang, lebar, dan kedalaman masing-masing adalah 1,2m; 1m; dan 3m serta peremajaan sekat-sekat (baffle) yang telah tua dan rusak dengan mengganti bahan sekat yang terbuat dari asbes menjadi pelat besi. Perubahan dan peremajaan settler pada unit sedimentasi yang telah tua dan rusak dengan mengganti bahan sekat yang terbuat dari asbes menjadi pelat besi. Dari hasil percobaan kolom sedimentasi dengan metoda Camp, didapatkan bahwa untuk R sama dengan 75persen, maka td sama dengan 5 menit dan Vs sama dengan 0,000184 m/detik. Untuk kapasitas instalasi sebesar 60 L/dtk maka panjang total zona pengendapan adalah 3 m dengan jumlah plate settler sebanyak 64 buah.

Deskripsi Alternatif :

ABSTRACT:




Perusahaan Daerah Air Minum (PDAM) Dago Pakar is one of the water treatment plant which supplied water in Bandung city. PDAM Dago Pakar has two water treatment plants now. One of them is paket system, where the treatment plant is not planned based on the treated characteristics of the water. It can make the treatment processes not operated well, so it can decrease the efficiency of the treatment.




The objective of the final report is evaluating Dago Pakar miniplant water treatment and to modify the units in the treatment plant to increase its productivity. So, it will get the design of the units in the treatment plant that can supply water in the south and east of Bandung.




Observation and measure in the treatment plant are including observe the unit operation and processes that occurred in the treatment plant, and measure the dimension of the units. Water sample is taken for raw water quality analysis to compare with Peraturan Pemerintah No. 82 Tahun 2001 and PERMENKES No. 907/MENKES/SK/VII/2002. Result of the evaluation of the units in the treatment plant show that the capacity of the treatment plant can be increased by adjust it to the pump capacity from 42 L/sec to 60 L/sec. The modificationof the units in the treatment plant are: Modification of the dimensions of flocculation unit with 1,2m of length, 1m of width, and 3m of height, and also change the baffles and substitute the material of the baffles from asbes with iron plate. Change and substitute the material of the settler in the sedimentation unit from asbes with iron plate. Result of the sedimentation unit with Camp method show that for R equal 75percent, so td equal 5 minutes, and Vs equal 0,000184 m/sec. For the 60 L/sec of capacity of the treatment plant so the total length of the settling zone is 6m with 64 plate settlers.

Copyrights : Copyright (c) 2007 FTSL ITB, Information Dissemination Right @ 2007 ITB Central Library, Jl. Ganesha 10 Bandung, 40132, Indonesia. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: James Nobelia Isnaniawardana, Ir., M.T.




    Scanner: Arnaz Driyastika M.




    (2007-12-12), Editor: driyastika

File PDF...