Perhitungan Intensitas Signal MRI (Magnetic Resonance Imaging)
Akibat Aliran Darah Dengan Metoda Simulasi

The compute MRI Signal Intensity to Blood Flow Effect
By Simulation Method

Master Theses from JBPTITBPP / 2001-08-22 11:27:00
Oleh : Yushardi, S2 - Physics (Yus_hard@yahoo.com)
Dibuat : 2000-10, dengan 1 file

Keyword : : Slice, Plugflow

Telah dibuat program simulasi hubungan Intensitas signal (I) terhadap beberapa parameter kecepatan aliran darah (Vo), panjang slice (l) dan sudut pemberian pulsa RF (q), dengan kondisi optimum (TE= 14 ms, TR= 52 ms) ,T1 =500 ms, T2= 200 ms, panjang coil (d= 10 cm) , pada aliran darah dengan menggunakan alat MRI (Magnetic Resonance Imaging). Adapun model profil aliran darah yang digunakan adalah Plugflow dengan teknik pemberian pulsa Refoccused Fast Gradient Echo, dengan pulsa kontinyu. Dari hasil simulasi diperoleh panjang slice optimum didapat pada l= 0.1 cm, dengan q = 90o. Sebagai pembanding hasil simulasi dengan menggunakan model dari “Jia-Hong-Gao” didapat slice optimum l = 0.3 cm pada Vo= 5 cm/s, q= 67.5o,dan l= 0.9 cm pada Vo=15cm/s,q=67.5o, dan l= 1.4 cm pada Vo= 25 cm/s,q=90o. Perbedaan hasil ini disebabkan pada model Jia-Hong Gao, kurva intensitas signal terhadap kecepatan diskontinu , secara tak langsung pada daerah tersebut perubahan panjang slice sangat elastis terhadap intensitas yang dihasilkan. Dari hasil simulasi kedua model tersebut memperlihatkan bahwa pada kecepatan aliran rendah sebaiknya digunakan slice yang kecil, dan semakin besar kecepatan sebaiknya panjang slice yang digunakan semakin besar

Deskripsi Alternatif :

It has been made the simulation program about relation of signal intensity ( I ) to parameters of blood flow velocity (Vo), slice length (l) and RF pulse angle (q), by optimum condition TE=14 ms, Tr=52 ms, T1= 500 ms, T2= 200ms, coil length (d= 10 cm), on blood flow to make use of MRI (Magnetic Resonance Imaging ) equipment. The blood flow profil model that be used in the simulation is Plugflow by given Refocused Fast Gradient Echo pulse technique with continous pulse. As the result of simulation show that optimum slice length is l = 0.1 cm with q= 90o. The other method Jia Gong How model show that optimum slice length is l=0.3 cm at Vo = 5 cm/s, q= 67.5o and l= 0.9 cm at Vo= 15 cm/s, q=67.5o and l= 1.4 cm at Vo 25 cm/s, q= 90o. The refference two model lie in the curve, the Hong Gao model signal intensity curve is made by diskontinu velocity. Indirectly in that range the slice length change is very elastic to intensity. The result of two simulation model show that the sort slice is good for small flow velocity, and for the faster flow velocity used the longer slice length.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Editor:

Download...