Path: TopS2-ThesesElectrical Engineering-STEI2009

KAJIAN DAMPAK BIOFOULING TERHADAP KINERJA KONDENSOR UNIT 4 PLTU MUARA KARANG

IMPACT STUDY ON PERFORMANCE CONDENSER BIOFOULING UNIT 4 MUARA KARANG POWER PLANT

Master Theses from JBPTITBPP / 2017-09-27 15:37:39
Oleh : RIZKI DWI KUSWORO (NIM 23207331), S2 - Electrical Engineering (e-mail: rizki@ptpjb.com)
Dibuat : 2009, dengan 1 file

Keyword : Efisiensi,biofouling,loses,backpressure,vakum kondensor.

Efisiensi pembangkit listrik tenaga uap banyak dipengaruhi berbagai macam hal,diantaranya dipengaruhi oleh tekanan kondensor yang naik akibat adanya biofouling yang menyebabkan penurunan kemampuan pendinginan dari kondensor. Pada sistim pendingin utama,karena menggunakan fluida air laut akan terjadi biofouling yang disebabkan tidak adanya treatment untuk mengatasi adanya biofouling tersebut, Melakukan kajian ini diharapkan dapat mengetahui gambaran umum kerugian yang terjadi akibat adanya dampak biofouling tersebut. Sehingga kita sadar dan dapat melakukan perbaikan agar loses tersebut tidak terjadi lagi. Kerugian yang terjadi akibat biofouling karena adanya lapisan film yang terbentuk dalam tube kondensor yang mengakibatkan penyempitan tube kondensor sehingga akan


menyebabkan penurunan volume aliran pendingin kondensor yang akan menaikkan backpressure ke turbin yang diakibatkan naiknnya tekanan kondensor atau vakum kondensor mengalami penurunan. Karena kondisi vakum yang drop inilah akan mengakibatkan biaya yang diperlukan untuk operasi pembangkit akan bertambah karena komsumsi bahan bakar yang dibutuhkan akan lebih banyak.

Deskripsi Alternatif :

Efficiency of steam power plants are significantly influenced by a variety of things, among others influenced by the condenser pressure rises due to biofouling which causes a decrease in cooling capacity of the condenser.


In the primary cooling system, because it uses sea water fluid will occur due to biofouling absence of treatment to overcome these biofouling. This review is expected to see an overview of losses are the result of the impact of biofouling. So we are aware and can make improvements so that loses does not happen again. Damage arising because of the biofouling film layer formed in condenser tubes that lead to narrowing of the tube condenser that will cause a decrease in the volume flow of cooling condenser backpressure will increase due to the turbine increasing condenser pressure or decreasing condenser vacuum. Because the vacuum that this drop will result in cost to plant operations will increase due to fuel consumption will need more.

Copyrights : Copyright Â(c) 2001 by ITB Central Library. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: Prof.Dr. Ngapuli I. Sinisuka, Editor: Vika A. Kovariansi

File PDF...