SISTEM DETEKSI KETIDAKSERAGAMAN DENSITAS DI DALAM BETON BERBASIS HAMBURAN SINAR GAMMA Co-60 MENGGUNAKAN PROGRAM SIMULASI GEANT4

DETECTION SYSTEM OF INHOMOGENEOUS DENSITY IN CONCRETE BASED ON GAMMA RAY SCATTERING Co-60 USING GEANT4 SIMULATION PROGRAM

Master Theses from JBPTITBPP / 2017-09-27 14:41:05
Oleh : MONA BERLIAN SARI (NIM : 20215026), S2 - Physics
Dibuat : 2017-01-13, dengan 7 file

Keyword : GEANT4, Sinar Gamma, Detektor NaI(Tl), NDT

Penelitian mengenai aplikasi hamburan sinar gamma untuk mendeteksi keberadaan rongga dan ketidakseragaman densitas di dalam beton telah dilakukan. Penelitian ini bertujuan untuk mengidentifikasi keberadaan rongga atau retakan di


bawah permukaan zat padat memanfaatkan kemampuan penetrasi sinar gamma ke dalam objek dan spektrum energi. Penelitian menggunakan pendekatan Monte Carlo dengan software simulasi GEANT4 untuk memodelkan konstruksi detektor dan mensimulasikan proses pengukuran spektrum distribusi energi sinar gamma pada pendeteksian rongga dan anomali densitas pada beton. Jenis detektor yang digunakan ialah detektor NaI(Tl) dengan sumber gamma Co-60 yang memiliki dua puncak fotolistrik yaitu pada level energi 1,17 MeV dan 1,33 MeV. Pada penelitian ini, detektor NaI(Tl) dilapisi oleh material MgO, Al, dan SiO2 pada bagian luarnya. Parameter yang diukur pada penelitian ini ialah puncak hamburan balik sinar gamma. Pada pengukuran respon detektor, pencocokan puncak energi fotolistrik hasil simulasi diverifikasi dengan data eksperimen. Dari hasil simulasi yang telah dilakukan diketahui bahwa kurva spektrum distribusi energi hamburan sinar gamma hasil simulasi menunjukkan pola yang sama dengan eksperimen sehingga sistem ini dapat diaplikasikan untuk uji tak merusak seperti investigasi keberadaan rongga dan ketidakseragaman densitas di dalam material beton. Melalui simulasi yang telah dilakukan dapat diketahui bahwa posisi penempatan detektor, keberadaan rongga, anomali densitas dan komposisi material pada beton mempengaruhi ketinggian puncak hamburan balik yang dihasilkan. Namun, penggunaan sinar gamma 60Co sebagai sumber foton lebih banyak diabsorpsi dibandingkan dengan jumlah foton yang terhambur sehingga kurang efektif untuk pengembangan sistem NDT menggunakan metode hamburan Compton.

Deskripsi Alternatif :

Research on application of gamma ray scattering to detect the presence of voids and inhomogeneous density in concrete has been done. This research aims to identify the presence of voids or cracks under area of solid surface using penetration ability of gamma rays into the object and energy spectrum. Research use Monte Carlo approach with GEANT4 simulation software to modelling detector construction and simulate measurement process of gamma rays energy distribution spectrum on existence of voids and inhomogeneous concrete density detection. The type of detector that used is NaI(Tl) detector with Co-60 gamma


source which has two photoelectric peaks in 1.17 MeV and 1.33 MeV energy level. In this research, NaI(Tl) detector coated by MgO, Al, and SiO2 material on the outside. The parameter that measured in this research is gamma ray


backscattering peak. In the measurement of detector responses, the peak of photoelectric energy from simulation results verified by experiments data. The curve of gamma ray scattering energy distribution spectrum from simulation


results has the same pattern with experiment such as this system could be applied for non-destructive testing like investigation of voids existence and inhomogeneous density of concrete material. The detector placement positions,


the presence of voids, inhomogeneous density and material composition of concrete affects backscattering peak generated. However, the use of 60Co as gamma rays source is less effective to development NDT system using Compton


scattering technique because of 60Co as energy source obtained more absorbed photons than scattered photons.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS2 - Physics
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing : Prof. Dr. -Ing. Mitra Djamal, Editor: Ratnasari

File PDF...