Path: TopS1-Final ProjectPetroleum Engineering-FTTM2009

ANALISIS SENSITIVITAS DALAM SUATU SISTEM JARINGAN PERPIPAAN LAPANGAN MINYAK

Undergraduate Theses from JBPTITBPP / 2017-09-27 10:37:30
Oleh : KETUT RAMA WIJAYA (NIM 12205045); Pembimbing: Ir. Leksono Mucharam, M.Sc., Ph.D., S1 - Department of Petroleum Engineering
Dibuat : 2009, dengan 1 file

Keyword : diameter mainline, panjang mainline, besar poma, laju alir

Tulisan ini bertujuan untuk menganalisis laju alir yang didapat di GS jika kita melakukan studi sensitivitas terhadap berbagai parameter desain seperti diameter mainline, panjang mainline, dan besarnya pompa. Studi dilakukan pada lapangan X yang diawali dengan pembuatan model base case. Hasil dari setiap kasus, yaitu perubahan terhadap base case akan dianalisis mengapa hal itu bisa terjadi, dan akhirnya nanti akan didapatkan panduan untuk mendapatkan desain yang optimal untuk lapangan ini.

Hasil simulasi menunjukkan bahwa perubahan diameter mainline dan lokasinya di mana perubahan itu dilakukan berpengaruh pada jumlah laju aliran yang mengalir pada tiap sumur, yang akan mempengaruhi total laju alir di GS. Begitu juga untuk parameter desain lain seperti panjang mainline dan besar pompa. Hasil terbaik adalah saat kita memperbesar diameter pada segmen pipa yang terdekat dengan GS, dan untuk pompa adalah saat kita memasang pompa dengan ukuran terbesar pada sumur 3 jika kita hanya bisa mengganti 1 pompa saja dari 7 sumur.

Deskripsi Alternatif :

The objective of this paper is to analyze the flow rate we get at GS if we do sensitivity studies to some design parameter such as mainline inside diameter, mainline length, and the pump size. The study done in Field X which started from building model for base case. The result from every cases, that showed by the difference from the base case will be analyzed why that result occurs and finally we will get the guide to do the optimal design for this field.

The simulation showed that the change of the mainline diameter and the location where we change it is influencing the flow rate in every well and also the total flow rate at GS. The other design parameter such as the mainline length and the pump size are also influential. The best result is when we upsize the diameter at the nearest section to the GS and for the pump size is when we put the biggest size of the pump in well 3 if we only could change 1 pump only from 7 wells.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: Ir. Leksono Mucharam, M.Sc., Ph.D., Editor: Vika A. Kovariansi

File PDF...