Path: Top > S2-Theses > Petroleum Engineering-FTTM > 2011

EVALUASI KEBIJAKAN ZERO WATER DISCHARGE BERDASARKAN ANALISIS SISTEM PRODUKSI SECARA TERINTEGRASI: STUDI KASUS RESERVOIR X

Evaluation of Zero Water Discharge Policy Using Integrated Production System Analysis: Case Study Reservoir X

Master Theses from JBPTITBPP / 2017-09-27 15:07:45
Oleh : INDRESVARI DEBORA NAPITUPULU (NIM : 22209052), S2 - Petroleum Engineering
Dibuat : 2011, dengan 8 file

Keyword : zero water discharge, pengelolaan dan pengolahan air terproduksi

Penginjeksian kembali air terproduksi ke reservoir menjadi solusi dari adanya kebijakan zero water discharge untuk mengurangi dampak negatif ke lingkungan


penerima. Tujuan dari penelitian ini adalah memaksimalkan recovery factor Reservoir X dengan melakukan optimasi sumur injeksi yang diperlukan untuk


membuang air terproduksi kembali ke reservoir yang mempertimbangkan komponen sumur, flowline, dan fasilitas pemisahan secara terintegrasi. Terdapat tujuh skenario injeksi dengan variasi sumur injeksi di tiga lokasi aquifer, sedangkan optimasi investasi pengolahan air terproduksi terdiri dari 3 skenario yaitu satu tahap, dua tahap, dan tiga tahap investasi. Skenario terbaik diambil berdasarkan pada pertimbangan teknis dan ekonomi dan dijadikan basecase untuk optimasi investasi pengolahan air selanjutnya yang mempunyai 3 skenario:


investasi setiap tahun, setiap 2 tahun, dan setiap 3-4 tahun pada periode dimana kenaikan laju produksi airnya tinggi. Hasil studi menunjukkan jumlah sumur injeksi yang optimum adalah satu dan berada di Aquifer 1; investasi pengolahan air 3 tahap menjadi basecase dan skenario dengan investasi 3-4 tahun memberikan nilai NPV yang tertinggi. Persentase biaya zero water discharge


terhadap total biaya proyek zero water discharge adalah 0,634%-1,606%.

Deskripsi Alternatif :

Re-injection of produced water has become a solution of zero water discharge policy to reduce negative impacts to the receiving environment. The objective of this research is to maximize the recovery factor of Reservoir X by performing optimization of injection wells to dispose of produced water back into the reservoir, by considering wells, flowlines, and water treatment as an integrated system. There are seven scenarios by varying injection wells at three different aquifer locations. Meanwhile, investments of produced water treatment consist of three scenarios: one stage, two stages, and three stages of investment. The best scenario was chosen based on technical and economic consideration which was


becomes basecase for the next investments of produced water treatment optimization that have 3 scenarios: every year, every 2 years, and every 3-4 years investment at the period in which the increment of water production rate is high. The study results are: the optimum number of injection is 1 at Aquifer 1; water treatment investment in 3 stages is a basecase and a scenario with 3-4 years of investment gives the highest NPV. Percentage of zero water discharge cost compared to total cost is in the range of 0.634%-1.606%.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id