ANALISA KEGAGALAN TUBE DI DALAM CRUDE HEATER TIPE KABIN DENGAN HORIZONTAL TUBE DAN NATURAL DRAFT BURNER

FAILURE ANALYSIS OF TUBE INSIDE CRUDE HEATER OF CABIN TYPE WITH HORIZONTAL TUBE AND NATURAL DRAFT BURNER

Master Theses from JBPTITBPP / 2017-09-27 14:53:51
Oleh : IMAN SUDIRMAN (NIM : 23107312); Pembimbing : Dr. Ir. H. Abdurrachim, S2 - Mechanical Engineering
Dibuat : 2011, dengan 9 file

Keyword : DMT, Ekspansi yang tertahan dan Luas perpindahan panas

Penelitian ini difokuskan pada Direct Fired Cude Heater (DFCH) yang terpasang pada salah satu pengumpul minyak (gathering station) di provinsi Kalimantan timur. Dua unit DFCH A & B yang diteliti mempunyai desain kapasitas beban

yang sama yaitu 18,0 MMBTU/hr. DFCH ini berfungsi untuk memanaskan liquid sebelum diproses lebih lanjut pada peralatan lain untuk pemisahan air dan DFCH pada liquid. DFCH #A telah beroperasi hampir 36 tahun sejak Mei 1975 dan

DFCH #B merupakan penambahan unit yang telah beroperasi hampir 15 tahun. Penggantian bagian tube yang rusak harus dilakukan setiap tahun pada DFCH #A. DFCH #B lebih handal dari #A, tetapi karena kadar CO pada gas buangnya lebih tinggi dari #A, maka efisiensinya lebih rendah.

Analisa yang dilakukan menggunakan pendekatan teori mengacu kepada perhitungan Lobo-Evans. Hasil-hasil pengukuran dan pengamatan dianalisa mengacu kepada standar API 573 dan hasil penelitian (journal). Untuk melengkapi analisa, perhitungan dilengkapi dengan perangkat lunak yang

dikembangkan oleh penulis dan software FLUENTTM sebagai pembanding.

Hasil analisa menunjukkan bahwa kerusakan yang terjadi pada tube adalah akibat dari perbedaan suhu yang terlalu tinggi antara liquid dan gas pembakaran di dalam crude heater. Perbedaan suhu yang besar ini disebabkan oleh luas permukaan perpindahan panas di area konveksi yang telalu kecil. Akibat lain dari keadaan ini akan mempercepat terbentuknya coke pada dinding dalam tube dan ekspansi arah

longitudinal yang berlebihan sehingga ekspansi tertahan pada dinding heater. Direkomendasikan untuk memperbaiki kerusakan tube dan juga menambah panjang tube pada area konveksi dan mengubah lay-out tube sehingga suhu permukaan luar tube dibawah suhu desain metal (DMT) maksimum sesuai

standard API STD 530 yaitu lebih kecil dari 540oC [15].

Deskripsi Alternatif :

Direct Fired Heater Cude (DFCH) were operated on gathering stations in East Kalimantan provience has been studied. Two units DFCH A & B have the same design load capacity of 18.0 MMBTU / hr. DFCH serves to heat the liquid before it is processed further in other equipment for the separation of water and crude in the liquid. DFCH #A has been operating nearly 36 years since May 1975 and DFCH #B is the addition of new units in operation 15 years. Replacement of damage tube section should be performed every year on DFCH # A. DFCH # B is more reliable than # A, but caused of the CO level in the flue gas is higher than # A, then the efficiency DFCH #B is lower than #A.

Computation was carried out using Lobo-Evans approach. The results of measurements and observations are analyzed referring to the standards of API 573 and journals. Numerical computation was developed by the author and the results were compared with FLUENTTM software.

It is concluded that tubes deteroritation were resulted by exceed of tube metal temperature (TMT) due to insufficient heat transfer area on convective zone. This condition will speed up coke formation on the inside tube wall of the tube and excessive expansion of tube on the longitudinal direction that was restricted by heater wall. It is recommended to increase the pipe length in the convective zone and change the tube lay-out in the heater so the tube metal temperature (TMT) will not exceed the allowable design metal temperature (DMT) of 540oC to meet standard API STD 530 [15].

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing : Dr. Ir. H. Abdurrachim, Editor: PKL-SMK

File PDF...