Path: TopS1-Final ProjectEnvironmental Engineering-FTSL2010

ANALISIS KUALITAS AIR BERDASARKAN PARAMETER KIMIA PADA SISTEM JARINGAN PENYEDIAAN AIR MINUM DI KOTA BANDUNG (STUDI KASUS PDAM DI DAGO PAKAR)

ANALYSIS OF WATER QUALITY BASED ON CHEMICAL PARAMETERS OF DRINKING WATER SUPPLY NETWORK SYSTEM IN BANDUNG (CASE STUDY: PDAM DAGO PAKAR)

Undergraduate Theses from JBPTITBPP / 2017-09-27 10:25:10
Oleh : HENNY PUSPITASARI (NIM 15306008); Pembimbing: Dr. Ir. Katharina Oginawati, M.S., S1 - Environmental Engineering Study Programme (henny.puspitasari@live.com)
Dibuat : 2010, dengan 1 file

Keyword : critical control point, kualitas air, WSP

Air merupakan salah satu kebutuhan pokok makhluk hidup. Water Safety Plan (WSP) yaitu optimasi sistem jaringan air minum dengan cara menemukan titik-titik kritis yang dianggap dapat membahayakan bagi kesehatan manusia karena rentan akan kontaminasi. Program ini dimaksudkan untuk memastikan kualitas air minum yang dihasilkan sudah memenuhi baku mutu dan aman dikonsumsi oleh masyarakat, sesuai dengan target berbasis kesehatan. Penelitian dilakukan dengan mengukur dan menguji parameter fisik dari kualitas air sesuai dengan Kepmenkes RI nomor 907/MenKes/SK/VII/2002. Terdapatnya berbagai zat-zat kimia yang memiliki efek langsung terhadap kesehatan manusia seperti besi,klorida, sulfat, zat organik dan nitrat. Dari hasil pengukuran dan pengujian tersebut, ditentukan titik kritis dan titik kendali kritis dari keseluruhan sistem penyediaan air minum perpipaan. Titik kritis ditentukan dari parameter yang melewati baku mutu. Dengan melihat sistem penyediaan air minum perpipaan secara keseluruhan, ditentukan tahap mana yang berpotensi sebagai titik kendali kritis. Hasil yang didapatkan menunjukkan bahwa analisa kualitas air pada parameter kimia pada seluruh sistem jaringan air minum di Dago Pakar dapat dikatakan aman untuk dikonsumsi dan tidak membahayakan kesehatan.

Deskripsi Alternatif :

Water is one of the basic needs of living things. Water Safety Plan (WSP), is the optimization of drinking water network system by finding critical points are considered to be harmful to human health because it vulnerable to contamination. This program is intended to ensure the quality of drinking water produced has met quality standards and are safe for consumption by society, according to health-based targets. Research done by measuring and testing the physical parameters of water quality according to the subsystem and RI 907/Menkes/SK/VII/2002 numbers. Presence of various chemical substances which have a direct effect on human health such as iron, chloride, sulfate, organic matter and nitrate. From the results of the measurement and testing, determined the critical point and critical control point of the entire water supply piping system. The critical point is determined from the parameters passed quality standards. By looking at the provision of potable water piping system in its entirety, what stage is determined that potentially as critical control points. The results obtained showed that water quality analysis on chemical parameters on the entire system of drinking water networks in Dago Pakar can fully be feasible to consume.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: Dr. Ir. Katharina Oginawati, M.S., Editor: Vika A. Kovariansi

Download...