Metoda geolistrik mise-a-la-masse adalah salah satu metoda geolistrik yang menginjeksikan arus langsung ketubuh bidang konduktif bawah permukaan dengan bantuan casing sumur bor.





Telah dilakukan eksperimen pada model analog 2 lapisan mirig berupa kumpulan resistor yang disusun secara 3D dan model lapangan sumur injeksi air yang dipantau antar waktu. Model lapangan berupa bak pasir berukuran 4x4 m. Pembuatan sumur kontrol dengan menempatkan sensor keberadaan air digunakan untuk mengetahui penyebaran dan posisi air pada kurun waktu tertentu.





Teknik pengukuran secara simultan dengan logger, memercepat pengambilan data. Satu kali pengukuran 64 elektroda secara grid mampu diselesaikan dengan waktu 15-20 menit. Pengukuran dilakukan antar waktu selama 5 jam injeksi air.





Hasil eksperimen menunjukan bahwa kemiringan lapisan berkorelasi langsung dengan kerapatan kontur resistivitas semu. Keberadaan dan pergerakan air bisa teridetifikasi dari harga resisitvitas yang semakin turun, akan tetapi keberadaan air tidak bisa diidentifikasi dengan nilai kontur tertentu.


Deskripsi Alternatif :

Mise-a-la-masse is a geoelectrical method which current directly injected to the subsurface conductive material through well casing.





The resistor arrangement model in such formed for representing of two rock layers which certain of dip. Field model formed as sand box 4x4 m which injected water will flows following certain dip. Control well which sensor plugged as a logger for determining water spread and position based on time.





Data logger applied in this experiment for fastening data measurement. By 64 grid-spread electrodes, 15-20 minutes data measured. The effect of water injection measured based on time to field model model conducted for 5 hour.





The experiment result shows the direct correlation of layer dip with apparent resistivity contour density. Water movement can be identified by decreasing of resistivity value, but not water existence.

Copyrights : Copyright Â(c) 2001 by ITB Central Library. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiCentral Library Institute Technology Bandung
Nama KontakDrs. Mahmudin, SIP.
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOdigilib@lib.itb.ac.id