Path: TopS2-ThesesCivil Engineering-FTSL2007

STUDI PARAMETER PENEMPATAN DAN RASIO MASSA TERHADAP EFEKTIFITAS MULTIPLE TUNED MASS DAMPERS

STUDY ON PLACEMENT AND MASS RATIO OF MULTIPLE TUNED MASS DAMPERS

Master Theses from JBPTITBPP / 2017-09-27 15:23:32
Oleh : Bahter Bukit (NIM 25004046), S2 - Civil Engineering
Dibuat : 2007-02-09, dengan 8 file

Keyword : Multiple Tuned Mass Dampers (MTMD), Mass Ratio, Maximum Displacement Ratio, MTMD Locations, Earthquake Load
Subjek : Civil Engineering
Kepala Subjek : Engineering
Nomor Panggil (DDC) : T 624.176 2 BUK

ABSTRAK:


Tujuan penelitian adalah menganalisis struktur dengan lokasi penempatan MTMD paling baik untuk menerima beban gempa dan menganalisis proporsi yang paling efektif dari rasio massa untuk masing-masing lokasi MTMD. Struktur yang ditinjau dalam analisis dinamik ini adalah struktur enam lantai dalam kondisi linear dan elastik. Struktur dimodelkan sebagai bangunan geser dua dimensi. Gaya luar pada struktur dengan sistem MTMD berasal dari percepatan tanah akibat gempa, yang diberikan dalam bentuk time history.


Keefektifan TMD dan MTMD dilihat dari rasio perpindahan maksimum dan reduksi simpangan tingkat. Analisis numerik dilakukan terhadap enam kondisi penempatan damper pada struktur. Kondisi pertaina penempatan TMD pada lantai 6, kedua penempatan MTMD pada lantai 6, ketiga penempatan MTMD di lantai 6 dan 4, keempat penempatan MTMD di lantai 6 dan 2, kelima penempatan MTMD di lantai 4 dan 2, dan keenam penempatan MTMD di lantai 6, 4, dan 2. Struktur enam lantai tanpa TMD digunakan sebagai pembanding.


Dari rasio perpindahan maksimum struktur dan reduksi simpangan tingkat (drift) maksimum maka terlihat kondisi penempatan MTMD di lantai 6 adalah paling efektif dari kondisi lain. Dengan bertambahnya rasio massa TMD dan total rasio massa MTMD maka sistem TMD dan MTMD semakin efektif. Dari basil analisis numerik menunjukkan penempatan TMD dan MTMD pada struktur mereduksi simpangan tingkat maksimum tetapi lokasi simpangan maksimum tidak berubah.

Deskripsi Alternatif :

ABSTRACT:


The objective of this research is to study the structure by placing MTMD to receive earthquake load and analyze the most effective proportion of mass ratio for each MTMD location. This dynamic analysis used a 6 story structure linear elastic as the main structure. Structure is modeled as two. The main external force is ground acceleration due to earthquake, which was given in the form of time history.


Maximum displacement ratio and drift shows the effectiveness of TMD and MTMD. Numerical anaysis was conducted in six damper placement conditions. First condition was TMD on 6th floor, second was MTMD on 6th, third was MTMD on 6th and 4th, fourth was MTMD on 6th and 2nd, fifth was MTMD on 4th and 2nd, and the last condition was MTMD placement on 6th, 4th, and 2nd. A six story structure without TMD was used as a comparison.


Based on structure maximum displacement ratio and maximum drift, the most effective MTMD placement condition was on the 6th floor. As TMD mass ratio and total MTMD mass ratio increases, the effectiveness of TMD and MTMD system also increased. Numerical analysis shows TMD and MTMD placement on structure reduces the maximum drift, but maximum deviation location was the same.

Copyrights : Copyright (c) 2007 FTSL ITB, Information Dissemination Right @ 2008 ITB Central Library, Jl. Ganesha 10 Bandung, 40132, Indonesia. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dyah Kusumastuti, Dr., Ir.


    Pembimbing 2: Rildova, Dr., Ir.


    Scan: Arnaz Driyastika M.


    (2008-01-30), Editor: driyastika