PENGARUH NILAI TIME ECHO TERHADAP KONTRAS DAN RESOLUSI CITRA T2-WEIGHT PHANTOM PADA METODA PENCITRAAN SPIN ECHO PULSE SEQUENCE

Undergraduate Theses from JBPTITBPP / 2017-09-27 11:45:15
Oleh : ALINE ZIVANA (NIM 10205062), S1 - Department of Physics
Dibuat : 2009, dengan 7 file

Keyword : magnetic resonance imaging (MRI), spin echo pulse sequence, T2-weight, contrast noise ratio (CNR), ROI, phantom

Magnetic Resonance Imaging (MRI) adalah suatu teknik penggambaran penampang tubuh berdasarkan prinsip resonansi magnetik inti atom hidrogen. Tehnik penggambaran MRI relatif komplek karena gambaran yang dihasilkan bergantung pada banyak parameter. Bila pemilihan parameternya tepat, kualitas gambar detil tubuh akan tampak jelas, sehingga anatomi dan patologi jaringan tubuh dapat dievaluasi secara teliti.

Pada tugas akhir ini dilakukan studi mengenai pengaruh nilai TE terhadap tingkat kontras dan resolusi citra T2-weight phantom dengan menggunakan metode pencitran spin echo pulse sequence pada pesawat MRI berkekuatan 0.5 Tesla di Rumah Sakit Hasan Sadikin Bandung. Pencitraan dilakukan dengan menggunakan variasi nilai TE dari nilai 46.8ms sampai 360ms dan menggunakan nilai TR yang tetap, yaitu 3500ms dengan nilai parameter pencitraan T2-weight lainnya yang tetap.

Dalam pencitraan T2-weight phantom ini diperoleh data ROI yang dipaparkan kedalam bentuk kurva T2 relaksasi untuk setiap kajian phantom sebagai penjelasan tingkat kontras citra. Selain itu, dilakukan pengecekan tingkat resolusi citra pada sisir tambahan (insert comb) phantom pada variasi nilai TE. Hasil yang diperoleh berupa kurva contrast noise ratio (CNR) dan grafik profil citra T2-weight phantom pada setiap variasi nilai TE.

Deskripsi Alternatif :

Magnetic Resonance Imaging (MRI) is a technical drawing based on the principle of the body section magnetic resonance hydrogen atom nucleus. Technical drawing of MRI is relatively complex because the resulting picture depends on many parameters. If the selecting parameters are right, the quality of the image body will be clear, so that the anatomy and pathology body network can be evaluated carefully.

This final project is done to study the influence of the value of the TE level image contrast and resolution T2-weight phantom by using spin echo pulse sequence imaging method on the MRI device with 0.5 Tesla in Hasan Sadikin Hospital,Bandung. Imaging uses variations of the value of TE 46.8ms to 360ms, and using a fixed TR of 3500ms with a value parameter imaging T2-weight is fixed too.

In T2-weight imaging, this phantom ROI data obtained were presented into the form of a curve T2 relaxation study for each level of explanation as a phantom image contrast. In addition, the level of image resolution is being checked on insert comb on the phantom variations TE value. Results obtained form curve contrast noise ratio (CNR) and graphic profile image phantom T2-weight variation in the value of each TE.

Copyrights : Copyright Â(c) 2001 by ITB Central Library. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS
Nama KontakUPT Perpustakaan ITB
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOinfo@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: Dr. Freddy Haryanto, Editor: Vika A. Kovariansi

File PDF...