PERHITUNGAN SEDERHANA PENENTUAN DOSIS SERAP MAKSIMUM SINAR-X DAN KAMERA GAMMA MENGGUNAKAN MATLAB

Undergraduate Theses from JBPTITBPP / 2009-12-28 09:30:01
Oleh : ADITIA ZULFIKAR (NIM 10205041), S1 - Department of Physics
Dibuat : 2009, dengan 6 file

Keyword : dosis serap, dosis ekivalen, dosis efektif, dosis ambang, proteksi radiasi, efek deterministik, efek stokastik, sinar-x, kamera gamma

Pada proses diagnosa penyakit kanker dapat digunakan berbagai macam teknik pencitraan dengan menggunakan alat modern yang prinsip dasarnya adalah memanfaatkan radiasi yang diantaranya sinar-X dan kamera gamma. Penggunaan alat radiodiagnosa tersebut dapat menimbulkan dampak negatif. Dampak negatif tersebut dapat merusak sel normal menjadi sel abnormal. Selain itu, hal ini juga dapat menyebabkan kematian, jika pemberian dosis penyinarannya melebihi batas ambang (nilai batas dosis) yang diperbolehkan. berdasarkan prinsip proteksi radiasi.

Pada tugas akhir ini akan dilakukan perhitungan sederhana untuk menentukan besaran dosis serap maksimum yang dapat diterima tubuh dari alat sinar-X dan kamera gamma dengan menggunakan Matlab. Perhitungan tersebut memasukkan faktor-faktor pengali yang mempengaruhi besaran dosis serap dan proteksi radiasi dari masing-masing alat tersebut. Akan dijelaskan pula mengenai dampak biologis yang kemungkinan dapat ditimbulkan jika dosis yang diberikan melebihi dosis ambang.

Deskripsi Alternatif :

There are various imaging methods that can be used in a cancer diagnostic process using modern equipments which based upon radiation principles, such as X-ray and gamma camera. These radiodiagnostic equipments can have negative impacts. That negative impact can damage the normal cells to become abnormal. Morever, further accumulation can even cause death if the amount of radiation exceeds the tolerable limits allowed by the radiation protection principles.

This final project provide a simple calculation to determine the maximum absorption dose. This dose related to the critical value in which a human body can sustain from the radiation of X-ray equipments and gamma camera. To achieve the objective, we incorporate Matlab to obtain the numerical results. In this work, we insert a certain multiplying factors that correlate to the absorption dose and radiation protections from each equipment. We also discussed about the biological impacts that might occur in case the radiation dose exceeds the threshold value.

Copyrights : Copyright Â(c) 2001 by ITB Central Library. Verbatim copying and distribution of this entire article is permitted by author in any medium, provided this notice is preserved.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBPP
OrganisasiS1 - Department of Physics
Nama KontakDrs. Mahmudin, SIP.
AlamatJl. Ganesha 10
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon62-22-2509118, 2500089
Fax62-22-2500089
E-mail Administratordigilib@lib.itb.ac.id
E-mail CKOdigilib@lib.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: Dr. rer. nat. Freddy Haryanto, Editor: Vika A. Kovariansi

Review...